The results of divertor studies on ASDEX Upgrade, at currents of up to 1.2 MA and heating powers up to 10 MW are described, with emphasis on the ELMy H-mode. The spatial and temporal characteristics of their heat load, and the simulation of ELMs by a time-dependent scrape-off layer code are described. High gas puff rates were found to lead to a large increase in divertor neutral pressure, at modest changes in ne, and to a strong reduction in time-averaged power flow and complete detachment from both target plates in between ELMs. Using pre-programmed puffs of neon and argon, the radiative power losses could be raised to 75% of the heating power, in H-regime discharges, and the regime of enhanced divertor neutral pressure was found also to lead to an improved pumping of recycling impurities.
ASDEX Upgradeにおけるダイバータ研究の結果について、最大1.2 MAの電流および最大10 MWの加熱出力の条件下で述べる。特にELMy Hモードに焦点を当てる。それらの熱負荷の空間的・時間的特性、および時間依存スクレイプオフ層コードによるELMのシミュレーションについて述べる。高いガス噴出率は、neの穏やかな変化のもとでダイバータ中性粒子圧力の大幅な増加をもたらし、またELM間における時間平均パワーフローの顕著な低減と両ターゲットプレートからの完全なデタッチメントをもたらすことが見出された。ネオンおよびアルゴンの事前プログラムされた噴出を用いることにより、Hモード放電において放射損失を加熱出力の75%まで高めることができた。また、ダイバータ中性粒子圧力の上昇した状態は、リサイクリング不純物の排気改善にもつながることが見出された。