The development of a large-area RF source for negative hydrogen ions, an official EFDA task agreement, is aiming at demonstrating ITER-relevant ion source parameters. This implies a current density of 200 A m−2 accelerated D− ions at a source filling pressure of ⩽0.3 Pa and an electron-to-ion ratio of ⩽1 from an extraction area similar to the positive-ion based sources at JET and ASDEX Upgrade and for pulse lengths of up to 1 h. The work is progressing along three lines in parallel: (i) optimization of current densities at low pressure and electron/ion ratio, utilizing small extraction areas (<0.01 m2) and short pulses (<6 s), in this parameter range the ITER requirements are met or even exceeded; (ii) investigation on extended extraction areas (<0.03 m2) and pulse lengths of up to 3600 s and (iii) investigation of a size-scaling on a half-size ITER plasma source. Three different test beds are being used to carry out these investigations in parallel. An extensive diagnostic and modelling programme accompanies the activities. The paper discusses the recent achievements and the status in these three areas of development.
公式のEFDAタスク協定である負水素イオン用大面積RF源の開発は、ITERに関連するイオン源パラメータを実証することを目的としている。これは、JETおよびASDEX Upgradeにおける正イオン源と同様の引き出し面積から、⩽0.3 Paのソース充填圧力、⩽1の電子対イオン比、最大1時間のパルス長で、200 A m−2の電流密度の加速D−イオンを意味する。この研究は、以下の3つの方向性に沿って並行して進められている。(i) 小さな引き出し面積(<0.01 m2)と短パルス(<6秒)を利用した、低圧力での電流密度と電子/イオン比の最適化。このパラメータ範囲では、ITER要件を満たすか、あるいは上回る。(ii) 拡大された引き出し面積(<0.03 m2)と最大3600秒のパルス長に関する調査、および(iii) 半分サイズのITERプラズマ源におけるサイズスケーリングの調査。これらの調査を並行して実施するために、3つの異なるテストベッドが使用されている。大規模な診断・モデリングプログラムがこれらの活動に付随している。本論文では、これら3つの開発分野における最近の成果と現状について議論する。