Ion saturation current (Isat) measurements made by three tips of a Langmuir probe array in the Large Helical Device are analysed for two plasma discharges. Absolute moment analysis is used to quantify properties on different temporal scales of the measured signals, which are bursty and intermittent. Strong coherent modes in some datasets are found to distort this analysis and are consequently removed from the time series by applying bandstop filters. Absolute moment analysis of the filtered data reveals two regions of power-law scaling, with the temporal scale τ ≈ 40 µs separating the two regimes. A comparison is made with similar results from the Mega-Amp Spherical Tokamak. The probability density function is studied and a monotonic relationship between connection length and skewness is found. Conditional averaging is used to characterize the average temporal shape of the largest intermittent bursts.
大型ヘリカル装置におけるラングミュアプローブアレイの3つの先端によって行われたイオン飽和電流(Isat)測定を、2つのプラズマ放電について解析した。絶対モーメント解析を用いて、バースト的かつ間欠的な測定信号の異なる時間スケールにおける特性を定量化した。いくつかのデータセットにおける強いコヒーレントモードがこの解析を歪めることが判明したため、バンドストップフィルタを適用して時系列から除去した。フィルタ処理後のデータに対する絶対モーメント解析により、2つの領域のべき乗則スケーリングが明らかになり、時間スケールτ≈40µsが2つの領域の境界となった。メガアンペア球状トカマクにおける類似の結果との比較を行った。確率密度関数を調べたところ、接続長と歪度の間に単調な関係が見出された。条件付き平均を用いて、最大の間欠的バーストの平均的な時間形状を特徴付けた。