Interpretative modelling of the SOL plasma in conventional (JET) and tight (MAST) aspect ratio devices has been performed using OSM2/EIRENE. A detailed comparison has been made of the solutions of the fluid equations and one key issue uncovered by this modelling is the significance of the mirror force for the spherical tokamak (ST) SOL. This force is proportional to ∇∥B/B, which is typically a factor 10 larger in an ST due to the low aspect ratio. This term leads to changes in the charged particle velocity distributions near regions with large V∥B/B representing an effective, upstream particle and momentum source. The modelling performed in this paper indicates that exclusion of the ∇∥B/B term may lead to incorrect conclusions on, for example, the upstream density, especially in STs.
従来型(JET)および緊密型(MAST)アスペクト比装置におけるSOLプラズマの解釈的モデリングを、OSM2/EIRENEを用いて実施した。流体方程式の解の詳細な比較が行われ、このモデリングによって明らかにされた重要な問題の一つは、球状トカマク(ST)のSOLにおけるミラー力の重要性である。この力は∇∥B/Bに比例し、低アスペクト比のためにSTでは典型的に10倍大きい。この項は、大きなV∥B/Bを有する領域付近での荷電粒子速度分布の変化をもたらし、効果的な上流の粒子および運動量源を表す。本論文で実施されたモデリングは、∇∥B/B項の除外が、特にSTにおいて、例えば上流密度に関する誤った結論につながる可能性があることを示している。