Core impurity accumulation can severely degrade plasma confinement and may even lead to disruptions; therefore, its mitigation is essential for achieving stable high-performance operation in tokamak devices. In this work, based on the OMFIT integrated modeling platform, the effects of electron cyclotron waves (ECWs) on core tungsten impurity transport are investigated in the HL-3 tokamak under an neutral beam injection (NBI)-heated background plasma. The simulation results show that, in the pure NBI case, the W impurity density profile exhibits pronounced central peaking, whereas ECW injection can effectively mitigate tungsten accumulation, with the control efficiency depending strongly on the power deposition location, injected ECW power, and current-drive scheme. Near-axis ECW deposition at ρ ≈ 0.1 and off-axis deposition at ρ ≈ 0.5 are found to be favorable impurity control schemes, whereas intermediate-radius deposition at ρ ≈ 0.3 provides a relatively weak suppression effect. The two effective deposition regions correspond to different dominant mechanisms: near-axis ECW deposition mainly alleviates W peaking by enhancing core turbulent transport and weakening inward convection, whereas off-axis deposition suppresses W accumulation primarily by flattening the main-ion density profile and thereby reducing the density-gradient-driven neoclassical inward pinch. For near-axis ECW deposition, the current-drive scheme has a significant influence on W transport. In the counter-current drive case, the increase in the local safety factor is accompanied by enhanced neoclassical inward convection, resulting in only limited mitigation of W peaking; by contrast, when ECW is deposited farther off axis, the W transport behavior is only weakly sensitive to the current-drive scheme. These results provide a physics basis for understanding impurity transport under high-power NBI heating and offer useful guidance for impurity control in the HL-3 tokamak.
コア不純物の蓄積はプラズマ閉じ込めを著しく劣化させ、さらにはディスラプションを引き起こす可能性があるため、その緩和はトカマク装置における安定した高性能運転を達成するために不可欠である。本研究では、OMFIT統合モデリングプラットフォームに基づき、中性粒子ビーム入射(NBI)加熱された背景プラズマ下のHL-3トカマクにおいて、電子サイクロトロン波(ECW)がコアタングステン不純物輸送に及ぼす影響を調査した。シミュレーション結果は、純NBIの場合、W不純物密度分布が顕著な中心ピーキングを示すのに対し、ECW入射はタングステン蓄積を効果的に緩和できることを示しており、その制御効率はパワー堆積位置、入射ECWパワー、および電流駆動方式に強く依存する。ρ ≈ 0.1での軸近傍ECW堆積とρ ≈ 0.5での軸外堆積は、好ましい不純物制御方式であることが見出されたが、ρ ≈ 0.3での中間半径堆積は比較的弱い抑制効果しか提供しない。この二つの有効な堆積領域は異なる支配メカニズムに対応する:軸近傍ECW堆積は、主にコア乱流輸送を強化し内向き対流を弱めることによってWピーキングを緩和するのに対し、軸外堆積は主に主イオン密度分布を平坦化し、それによって密度勾配駆動の新古典内向きピンチを低減することによってW蓄積を抑制する。軸近傍ECW堆積の場合、電流駆動方式はW輸送に有意な影響を及ぼす。反電流駆動の場合、局所安全係数の増加は新古典内向き対流の強化を伴い、その結果Wピーキングの緩和は限定的となる。対照的に、ECWがより軸外に堆積される場合、W輸送挙動は電流駆動方式に対して弱い感度しか示さない。これらの結果は、高パワーNBI加熱下での不純物輸送を理解するための物理的基盤を提供し、HL-3トカマクにおける不純物制御に有用な指針を与える。