A molecular cluster injector (MCI) has been developed to provide short-pulse, high-density fuelling for the lithium tokamak experiment (LTX). Using an electron-beam fluorescence method, the molecular density profiles produced by the injector are measured with sub-cm spatial resolution. The system, which is cryogenically cooled to promote the formation of molecular clusters, demonstrates a significant increase in molecular density relative to room-temperature supersonic gas injectors. The transient characteristics of short pulses (3–5 ms) are measured with 250 µs temporal resolution, and the jet shock structure is found to evolve significantly on that time scale. Supplemental measurements with a pressure transducer validate the electron-beam measurements. The measured density profiles are consistent with supersonic flows suitable for producing substantial populations of molecular clusters. The measured densities and flow rates are appropriate for high-density fuelling of LTX plasmas. The MCI will be used to investigate the physics of molecular cluster fuelling of LTX plasmas.
リチウムトカマク実験装置(LTX)用の短パルス・高密度燃料供給を実現するため、分子クラスター入射器(MCI)を開発した。電子ビーム蛍光法を用いて、入射器が生成する分子密度分布をサブcmの空間分解能で測定した。分子クラスターの形成を促進するために極低温に冷却される本システムは、室温の超音速ガス入射器と比較して、分子密度が有意に増加することを実証した。短パルス(3〜5 ms)の過渡特性を250 µsの時間分解能で測定し、ジェット衝撃波構造がその時間スケールで有意に発展することが判明した。圧力変換器による補足的測定により、電子ビーム測定の妥当性を検証した。測定された密度分布は、分子クラスターの実質的な集団を生成するのに適した超音速流と一致する。測定された密度と流量は、LTXプラズマの高密度燃料供給に適している。MCIは、LTXプラズマへの分子クラスター燃料供給の物理を調査するために使用される予定である。