The large-aspect-ratio model for current-driven external kinks is applied to study control of non-axisymmetric resistive wall modes in tokamaks. Comparison with toroidal computations indicates that the cylindrical instabilities react in similar ways to feedback as the pressure-driven toroidal modes, when the feedback and sensor coils are placed on the low-field side of the torus. However, higher gain is required in the cylindrical case. The cylindrical model is used to gain insights into design issues concerning a feedback system for ITER, with a double wall and superconducting coils. Good control performance and acceptable coilvoltages are found in an initial value problem, where the initial conditions correspond to expected noise levels, when sensors for the poloidal field are placed inside the first wall. This can be accomplished with a PI (proportional plus integral) controller from the voltages of the sensor loops to the voltage over the active coils. The two-wall structure of ITER makes control somewhat more demanding than for tokamaks with a single wall. Adequate control can be achieved also when poloidal sensors are placed outside a single wall, but this requires additional derivative action (PID) and the resulting voltages are significantly higher.
電流駆動外部キンクに対する大アスペクト比モデルを、トカマクにおける非軸対称抵抗性壁モードの制御の研究に適用する。トロイダル計算との比較は、フィードバックコイルとセンサーコイルがトーラスの低磁場側に配置されている場合、円筒不安定性は圧力駆動トロイダルモードと同様の方法でフィードバックに反応することを示している。しかしながら、円筒の場合にはより高いゲインが必要である。円筒モデルは、二重壁と超伝導コイルを備えたITER用フィードバックシステムに関する設計上の問題への洞察を得るために使用される。初期条件が予想されるノイズレベルに対応する初期値問題において、ポロイダル磁場センサーが第一壁の内側に配置されている場合、良好な制御性能と許容可能なコイル電圧が見いだされる。これは、センサーループの電圧から能動コイルの両端の電圧へのPI(比例+積分)コントローラーによって達成できる。ITERの二重壁構造は、単一壁のトカマクの場合よりも制御をいくぶん困難にする。適切な制御は、ポロイダルセンサーが単一壁の外側に配置されている場合にも達成できるが、これには追加の微分動作(PID)が必要であり、結果として生じる電圧は著しく高くなる。