In future fusion reactors, measuring the neutron production rate from deuterium–tritium (DT) fusion reactions will be crucial as it indicates fusion performance. To optimize Tritium consumption and limit neutron activation, a support function included in the plasma control system called a dud detector will trigger an alarm if the plasma fails to achieve expected fusion performance. This function has been developed and routinely employed at Joint European Torus during DT campaigns. This study presents machine-learning methods based on a surrogate model of the neutron rate, which can be used as an advanced dud detector. In preparation for DT operations in BEST, HL-3, ITER and SPARC, we investigate the portability and inherent limitations of these machine learning methods by analyzing similar DT experiments conducted at Tokamak Fusion Test Reactor.
将来の核融合炉において、重水素–トリチウム(DT)核融合反応による中性子生成率の測定は、核融合性能を示す指標として極めて重要となる。トリチウム消費の最適化と中性子放射化の制限のため、プラズマ制御システムに含まれる支援機能であるdud検出器は、プラズマが期待される核融合性能を達成できない場合に警報を発する。この機能は、Joint European TorusにおけるDTキャンペーン中に開発され、日常的に使用されてきた。本研究では、中性子率のサロゲートモデルに基づく機械学習手法を提示し、これを高度なdud検出器として使用できることを示す。BEST、HL-3、ITER、SPARCにおけるDT運転に備え、Tokamak Fusion Test Reactorで実施された類似のDT実験を解析することにより、これらの機械学習手法の移植性と固有の限界を調査する。