Spurious magnetic field perturbations, known as error fields (EFs) with toroidal mode number n = 2 can have deleterious effects similar to those associated with n = 1 EFs. An n = 2 EF source is expected in MAST-U because the poloidal field coils P4 and P5, retained from the previous device MAST, exhibit n = 1 and n = 2 deformations due to coil manufacturing imperfections. This work presents the n = 2 EF identification studies carried out in MAST-U. The n = 2 compass scan indicates that, for 750 kA plasma current, double-null divertor H-mode plasmas, the n = 2 EF is relatively small when assessed using locked mode onset and rotation braking as metrics, suggesting that the n = 2 EF is effectively screened by the plasma in this scenario. Furthermore, during the n = 2 EF identification studies, an interesting interplay between the onset times of n = 1 and n = 2 rotating modes and plasma rotation was observed. This observation enables the identification of control strategies aimed at delaying the onset of n = 1 and n = 2 MHD modes while sustaining plasma rotation.
トロイダルモード数n = 2を有する誤差磁場摂動(EF)として知られるスプリアス磁場擾乱は、n = 1のEFに関連するものと同様の有害な影響を及ぼし得る。n = 2のEF源はMAST-Uにおいて存在すると予想される。なぜなら、以前の装置MASTから引き継がれたポロイダル磁場コイルP4およびP5が、コイル製造上の不完全性に起因するn = 1およびn = 2の変形を示すためである。本稿では、MAST-Uにおいて実施されたn = 2のEF同定研究を提示する。n = 2のコンパススキャンは、750 kAのプラズマ電流、ダブルヌルダイバータHモードプラズマにおいて、ロックモード発生および回転制動を指標として評価した場合、n = 2のEFが比較的小さいことを示しており、このシナリオではn = 2のEFがプラズマによって効果的に遮蔽されていることを示唆している。さらに、n = 2のEF同定研究の過程で、n = 1およびn = 2の回転モードの発生時刻とプラズマ回転との間の興味深い相互作用が観察された。この観察により、プラズマ回転を維持しつつn = 1およびn = 2のMHDモードの発生を遅延させることを目的とした制御戦略の同定が可能となる。