AbstractThe reradiated heat flux in the NET/ITER plasma chamber and its effects on the thermal behaviour of the plasma facing components are analyzed under transient conditions for normal loadings and for the abnormal case of loss of cooling in the divertor. The axisymmetry and the actual geometry and thermal loading distribution in the presently envisaged plasma chamber configuration are taken into account and the heat removal in the divertor and first wall adequately modelled. The protection material considered is CFC composite brazed on the divertor TZM heat sink and mechanically attached to the 316L first wall structure with either conduction - or radiation - cooling at inboard and outboard.The results show among other things that significant heat flux can be reradiated. In the most favourable case (conductive protection at inboard and radiative at outboard) 0.28 MW/m2 is reradiated at the equatorial zone of the outboard first wall for a nominal peak heat flux of 0.6 MW/m2. However even in this case, the maximum steady state CFC temperature (∼ 1800°C for a 15 mm tile thickness) is probably too high for the requirements of plasma material interaction. Thus the viability of this radiativity cooled protection is questionable for pulses longer than − 200 s.
NET/ITERプラズマ容器内の再放射熱流束と、プラズマ対向機器の熱挙動に及ぼすその影響は、通常負荷およびダイバータにおける冷却喪失という異常ケースの過渡条件下で解析される。現在想定されているプラズマ容器構成における軸対称性、実際の形状、および熱負荷分布が考慮され、ダイバータおよび第一壁における除熱が適切にモデル化される。考慮される保護材料は、ダイバータのTZMヒートシンクにろう付けされ、316L第一壁構造に機械的に取り付けられたCFC複合材料であり、インボードおよびアウトボードにおいて伝導冷却または放射冷却のいずれかを備える。結果は、とりわけ、かなりの熱流束が再放射され得ることを示している。最も好ましいケース(インボードでの伝導保護、アウトボードでの放射保護)では、公称ピーク熱流束0.6 MW/m2に対して、アウトボード第一壁の赤道領域で0.28 MW/m2が再放射される。しかしながら、この場合でも、最大定常状態におけるCFC温度(15 mmタイル厚さで約1800°C)は、プラズマ材料相互作用の要件に対しておそらく高すぎる。したがって、この放射冷却保護の実現可能性は、−200秒より長いパルスに対して疑問視される。