Experiments of disruption mitigation with massive gas injection have been conducted in J-TEXT tokamak with various impurities (He, Ne, Ar and He&Ar (90%:10%) mixtures) injection. A 17-channels polarimeter-interferometer (POLARIS) has been used to analyze the evolution of the electron density profile during pre-TQ and TQ phases. Experiments show that both the impurity species and applied high voltage of the valve have an obvious influence on the impurities deposition location and electron density profile. Moreover, with the high spatial resolution of POLARIS, a rather accurate impurity mixing efficiency has been obtained. The results show that Ar, the high atomic number (high-Z) impurity, has high cooling efficiency and evident mitigation effects, but the mixing efficiency for Ar is only of order 5%–8%. As for the low-Z impurity, He has fast propagation velocity and can reach high mixing efficiency, which is found to be of order 20%–40%. The use of the mixtures of high-Z and low-Z impurities (He&Ar (90%:10%)) can combine the fast penetration of He and high cooling efficiency of Ar, and the mixing efficiency is up to the order 20%–40%, improving the disruption mitigation efficiency and time response of disruption mitigation system.
J-TEXTトカマクにおいて、種々の不純物(He、Ne、ArおよびHe&Ar(90%:10%)混合ガス)を用いた大量ガス入射によるディスラプション緩和実験を実施した。17チャンネル偏光計-干渉計(POLARIS)を用いて、プレディスラプション(pre-TQ)およびディスラプション(TQ)位相における電子密度分布の時間発展を解析した。実験結果から、不純物の種類およびバルブへの印加電圧が、不純物の堆積位置と電子密度分布に顕著な影響を及ぼすことが示された。さらに、POLARISの高い空間分解能により、不純物混合効率を高精度で評価することができた。その結果、高Z不純物であるArは高い冷却効率と明確な緩和効果を示すものの、Arの混合効率はわずか5%~8%程度であることが明らかとなった。一方、低Z不純物であるHeは高速の伝播速度を有し、20%~40%程度の高い混合効率が達成可能であることが見出された。高Zおよび低Z不純物の混合ガス(He&Ar(90%:10%))を用いることで、Heの高速伝播特性とArの高い冷却効率を組み合わせることができ、混合効率は20%~40%程度に達し、ディスラプション緩和システムの緩和効率と応答時間が改善された。