X-ray imaging crystal spectrometers with high spectral and spatial resolution are currently being used on magnetically confined fusion devices to infer the time history profiles of ion and electron temperatures as well as plasma flow velocities. The absolute measurement of flow velocities is important for optimizing various discharge scenarios and evaluating the radial electric field in tokamak and stellarator plasmas. Recent studies indicate that the crystal temperature must be kept constant to within a fraction of a degree to avoid changes of the interplanar 2d-spacing by thermal expansion that cause changes in the Bragg angle, which could be misinterpreted as Doppler shifts. For the instrumental parameters of the x-ray crystal spectrometer on Alcator C-Mod, where those thermal effects were investigated, a change of the crystal temperature by 1 °C causes a change of the lattice spacing of the order of Δd = 1 × 10−5 Å introducing a fictitious velocity drift of the order of ∼3 km s−1. This effect must be considered for x-ray imaging crystals spectrometers installed on LHD, KSTAR, EAST, J-TEXT, NSTX and, in the future, W7-X and ITER.
高スペクトル分解能と高空間分解能を備えたX線イメージング結晶分光器は、現在、磁場閉じ込め核融合装置において、イオン温度と電子温度の時間履歴プロファイル、ならびにプラズマ流速を推定するために使用されている。流速の絶対測定は、様々な放電シナリオの最適化や、トカマクおよびステラレータプラズマにおける動径電場の評価にとって重要である。最近の研究によれば、結晶温度を数分の1度以内に一定に保たなければ、熱膨張による格子面間隔(2d)の変化がブラッグ角の変化を引き起こし、それがドップラーシフトと誤解釈される可能性がある。Alcator C-ModのX線結晶分光器の機器パラメータについて、これらの熱的影響が調査されたが、結晶温度が1°C変化すると、格子定数の変化はΔd = 1 × 10⁻⁵ Åのオーダーとなり、見かけ上の速度ドリフトは約3 km/sのオーダーになる。この影響は、LHD、KSTAR、EAST、J-TEXT、NSTX、そして将来的にはW7-XやITERに設置されるX線イメージング結晶分光器においても考慮されなければならない。