The distribution of particles and power flux to plasma-facing components play a critical role in the design of next-generation fusion devices. In particular, it is a challenge to bring down the peak heat fluxes onto the divertor to manageable levels (of order 5 MW ). A large value of connection length (Lc) increases the role of cross-field transport and may lead to broader power deposition profile and lower peak heat fluxes. In low-shear stellarators like Wendelstein 7-X (W7-X) very long connection lengths, about one order of magnitude longer than those of equal-sized tokamaks, can be achieved. The flexibility of W7-X coil system allows variation of connection lengths significantly. This paper describes numerical studies that identify magnetic configurations in W7-X with particularly large and particularly small Lc; thus, the effects of Lc on divertor operation can be effectively studied. It is found that a variation of a factor of 8 is possible, with average Lc values as large as 426 m for a configuration developed here. It is also shown that Lc itself, for a given magnetic configuration, varies strongly, potentially complicating an experimental analysis of its effects.
プラズマ対向機器への粒子およびパワーフラックスの分布は、次世代核融合装置の設計において決定的な役割を果たす。特に、ダイバータへのピーク熱流束を管理可能なレベル(約5 MW のオーダー)まで低減することは課題である。接続長(Lc)の大きな値は、磁場横断輸送の役割を増大させ、より広いパワー堆積分布とより低いピーク熱流束をもたらす可能性がある。ヴェンデルシュタイン7-X(W7-X)のような低シア・ステラレータでは、同規模のトカマクよりも約1桁長い非常に長い接続長を達成できる。W7-Xのコイルシステムの柔軟性により、接続長を大幅に変化させることが可能である。本論文は、W7-Xにおいて特に長いLcおよび特に短いLcを持つ磁気配位を特定する数値研究を記述するものであり、これによりLcがダイバータ運転に及ぼす影響を効果的に研究できる。ここで開発された配位では、平均Lc値が426 mにも達し、8倍の変動が可能であることが見出された。また、特定の磁気配位においてLc自体が大きく変動し、その影響の実験的解析を潜在的に複雑にすることも示される。