AbstractDuring the June 1999 JET shutdown, 3000 plasma facing Tile Assemblies were found to be loose and had to be re-torqued remotely using the Mascot force reflecting manipulator. Whilst the integrity of these Tile Assemblies has been monitored during previous man access shutdowns, with the introduction of tritium to the machine in May 1996, the majority had not been checked since March 1996. This paper reviews typical plasma facing Tile Assembly designs within the JET torus and summarises the experience gained for use in future machine applications. This includes loosening processes/mechanisms and their prevention, applications of surface coatings to avoid seizing of un-lubricated assemblies, and the use of vibration resistant thread profiles. The design of attachments to minimise combined mechanical and thermal stresses in the tiles, material selection and other engineering aspects are also discussed.
1999年6月のJET運転停止期間中、約3000個のプラズマ対向タイルアセンブリが緩んでいることが判明し、Mascot力反射マニピュレータを用いて遠隔で再締め付けを行う必要があった。これらのタイルアセンブリの健全性は、これまでの有人アクセスによる運転停止期間中に監視されてきたが、1996年5月にトリチウムが装置へ導入されて以降、大部分は1996年3月以降点検されていなかった。本論文は、JETトーラス内の代表的なプラズマ対向タイルアセンブリ設計を概説し、今後の装置応用に向けて得られた知見をまとめるものである。これには、緩みのプロセス/メカニズムとその防止策、無潤滑アセンブリの焼付きを回避するための表面コーティングの適用、および耐振動ねじ山形状の使用が含まれる。タイルにおける機械的応力と熱的応力の複合を最小化するための取付設計、材料選定、その他の工学的側面についても議論する。